Thursday, December 13, 2018

5 Advisories and 2 Updates Published – 12-13-18

Today the DHS NCCIC-ICS published four control system security advisories for products from GE, Geutebruck, Siemens and Schneider and one medical device security advisory for products from Medtronic. They also published an update for a previously published control system security advisory for products from Siemens and a medical device security advisory for products from Philips.

GE Advisory


This advisory describes a path traversal vulnerability in the GE Mark VIe, EX2100e, EX2100e_Reg, and LS2100e distributed control systems. The vulnerability was reported by Can Demirel of Biznet Bilisim. GE has a new version that mitigates the vulnerability. There is no indication that Demirel has been provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reports that a relatively low-skilled attacker with uncharacterized access could exploit the vulnerability to access system data, which could result in escalation of privilege and unauthorized access to the controller.

Geutebruck Advisory


This advisory describes an OS command injection vulnerability in the Geutebruck E2 Camera Series. The vulnerability was reported by Davy Douhine of RandoriSec. Geutebruck has a new version that mitigates the vulnerability. There is no indication that Douhine has been provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit the vulnerability to allow a remote attacker to inject OS commands as root.

Siemens Advisory


This advisory describes two improper input validation vulnerabilities in the Siemens EN100 Ethernet Communication Module and SIPROTEC 5 relays. These vulnerabilities were reported by Victor Nikitin, Vladislav Suchkov, and Ilya Karpov from ScadaX. Siemens has updates for some of the affected products and continues to work on updates for the remaining products.

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit the vulnerabilities to cause a denial-of-service condition of the network functionality of the device, compromising the availability of the system.

NOTE: This advisory was published when Siemens published an update last Tuesday. The original Siemens advisory was reported here back in July, 2018.

Schneider Advisory


This advisory describes three vulnerabilities in the Schneider Electric GUIcon. The vulnerabilities were reported by mdm and rgod of 9SG Security Team. Schneider has a new version that mitigates the vulnerabilities. There is no indication that the researchers were provided an opportunity to verify the efficacy of the fix.

The three reported vulnerabilities are:

• Type confusion (2) - CVE-2018-7813 and CVE-2018-7815; and
• Stack-based buffer overflow - CVE-2018-7814

NCCIC-ICS reports that a relatively low-skilled attacker with uncharacterized access could exploit the vulnerabilities to execute code with privileges within the context of the application.

NOTE: I briefly reported the Schneider advisory last Saturday.

Medtronic Advisory


This advisory describes a missing encryption of sensitive data vulnerability in the Medtronic 9790 CareLink Programmer, 2090 CareLink Programmer, 29901 Encore Programmer; programmers for Medtronic cardiac devices. The vulnerabilities were reported by Researchers Billy Rios and Jonathan Butts of Whitescope LLC. Medtronic has provided generic workarounds for two of the devices and reports that the 9970 is out of support and all use should be discontinued. There is no indication that the researchers have been provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reports that an relatively low-skilled attacker with physical access to the devices could exploit the vulnerability to access PHI or PII stored on the device.

Siemens Update

This update provides additional information for an advisory that was originally published on March 29th, 2018 and updated on April 24th, 2018, June 12th, 2018 and again on November 14th, 2018. The update provides updated affected version information and mitigation links for SIMATIC NET PC-Software.

NOTE: Siemens updated their advisory on Tuesday and then again today. This NCCIC-ICS update reflects the corrected information published by Siemens today.

Philips Update


This update provides additional information for an advisory that was originally published on March 27th, 2018 and subsequently updated on December 11th, 2018. The updated information includes revised affected version data.

More Missing Siemens Updates


Siemens published four more updates today; only one of those was addressed by NCCIC-ICS today. It will be a long blog post here on Saturday. 

Tuesday, August 7, 2018

ICS-CERT Publishes 3 Advisories


Today the DHS ICS-CERT published one control system security advisory for products from Delta Electronics and two medical device security advisories for products from Medtronic.

Delta Advisory


This advisory describes two vulnerabilities in the Delta CNCSoft and ScreenEditor products. The vulnerability was reported by Mat Powell via the Zero Day Initiative. Delta has an updated version of CNCSoft that mitigates the vulnerabilities. There is no indication that Powell was provided an opportunity to verify the efficacy of the fix.

The two reported vulnerabilities are:

• Stack-based buffer overflow - CVE-2018-10636; and
Out-of-bounds read - CVE-2018-10598

ICS-CERT reports that a relatively low-skilled attacker could remotely exploit the vulnerability to gain remote code execution with administrator privileges.

MiniMed Advisory


This advisory describes two vulnerabilities in the Medtronic MiniMed 508 Insulin Pump. The vulnerabilities were reported by Billy Rios, Jesse Young, and Jonathan Butts of Whitescope LLC. Medtronic does not intend to develop a mitigation for these vulnerabilities (see note below).

The two reported vulnerabilities are:

• Cleartext transmission of sensitive information - CVE-2018-10634; and
• Authentication bypass by capture replay - CVE-2018-14781

ICS-CERT reports that an uncharacterized attacker could remotely exploit these vulnerabilities to allow an attacker to replay captured wireless communications and cause an insulin (bolus) delivery.

NOTE: The Medtronic security advisory reports that the following must occur for these vulnerabilities to be exploited:

1. The remote option for the pump would need to be enabled. This is not a factory-delivered default, and a user must choose this option.
2. The user’s remote controller ID needs to be registered to the pump.
3. The easy bolus option would need to be turned on and easy bolus step size programmed in the pump.
4. An unauthorized individual would need to be within close proximity to the user, with
necessary equipment to copy the RF signals activated, when the user is delivering a bolus
using the remote controller.
5. The unauthorized individual would need to be within the vicinity of the userto play back the RF signals to deliver a malicious remote bolus.
6. The user would need to ignore the pump alerts, which indicates that a remote bolus is being delivered.

MyCareLink Advisory


This advisory describes two vulnerabilities in the Medtronic MyCareLink Patient Monitor. The vulnerabilities were reported by Billy Rios, Jesse Young, and Jonathan Butts of Whitescope LLC. Medtronic is making (has made for one of the vulnerabilities) server side updates to mitigate the vulnerabilities. There is no indication that the researchers have been provided an opportunity to verify the efficacy of the fix.

The two reported vulnerabilities are:

• Insufficient verification of data authenticity - CVE-2018-10626; and
• Storing passwords in a recoverable format - CVE-2018-10622

ICS-CERT reports that an uncharacterized attacker with physical access to the device could exploit the vulnerabilities to obtain per-product credentials that are utilized to authenticate data uploads and encrypt data at rest. Additionally, an attacker with access to a set of these credentials and additional identifiers can upload invalid data to the Medtronic CareLink network.

Wednesday, February 28, 2018

ICS-CERT Publishes 5 Advisories and 5 Siemens Updates


Yesterday the DHS ICS-CERT published two medical device security advisories for products from Philips and Medtronic. They published three industrial control system security advisories for products from Emerson, Delta Electronics and Siemens. They also updated five previously published control system security advisories for a variety of products from Siemens.

NOTE: The Siemens advisory and five updates were briefly mentioned here last week. There was another advisory and another update (both 3rd party vendor problems affecting Siemens products) that Siemens announced at the same time that ICS-CERT has apparently decided not to address.

ICS-CERT also recently announced a call for abstracts for the Spring 2018 meeting of the ICSJWG in Albuquerque, NM on April 10 - 12, 2018. Abstracts need to be submitted by March 13th, 2018.

Philips Advisory


This advisory describes a relatively large number of vulnerabilities in the Philips Intellispace Portal ISP visualization and image analysis system. The vulnerabilities are apparently being self-reported. There is no report about these vulnerabilities on the FDA medical device safety page. Philips will be issuing an updated version in the coming months to mitigate the vulnerabilities.

NOTE: Apparently at least some of these vulnerabilities are 3rd party vendor issues that have seen publicly available exploits in other products.

The 35 reported vulnerabilities include:

• Improper input validation (13) - CVE-2018-5474, CVE-2017-0143, CVE-2017-0144, CVE-2017-0145, CVE-2017-0146, CVE-2017-0148, CVE-2017-0272, CVE-2017-0277, CVE-2017-0278, CVE-2017-0279, CVE-2017-0269, CVE-2017-0273, and CVE-2017-0280;
• Information exposure (8) - CVE-2017-0147, CVE-2017-0267, CVE-2017-0268, CVE-2017-0270, CVE-2017-0271, CVE-2017-0274, CVE-2017-0275, and CVE-2017-0276;
• Permissions, privileges and access controls (4) - CVE-2018-5472, CVE-2018-5468, CVE-2017-0199, and CVE-2005-1794;
• Unquoted search path element - CVE-2018-5470;
• Left over debug code - CVE-2018-5454; and
Cryptographic issues (8) - CVE-2018-5458, CVE-2018-5462, CVE-2018-5464, CVE-2018-5466, CVE-2011-3389, CVE-2004-2761, CVE-2014-3566, and CVE-2016-2183

ICS-CERT reports that an uncharacterized attacker could remotely exploit these vulnerabilities  to gain unauthorized access to sensitive information, perform man-in-the-middle attacks, create denial of service conditions, or execute arbitrary code.

Medtronic Advisory


This advisory describes two vulnerabilities in the Medtronic 2090 CareLink Programmers. The vulnerabilities were reported by Billy Rios and Jonathan Butts of Whitescope LLC. There is no report about these vulnerabilities on the FDA medical device safety page. Medtronics has identified compensating controls that mitigate the vulnerability. There is no indication that the researchers have been provided an opportunity to verify the efficacy of the fix.

The two reported vulnerabilities are:

• Strong password in a recoverable format - CVE-2018-5446; and
• Relative path traversal - CVE-2018-5448

ICS-CERT reports that an uncharacterized attacker with access to a CareLink Programmer could exploit the vulnerability to obtain per-product credentials to the software deployment network. These credentials grant access to the software deployment network, but access is limited to read-only versions of device software applications. No write capability exists with the credentials.

Emerson Advisory


This advisory describes a stack-based buffer overflow vulnerability in the Emerson ControlWave Micro Process Automation Controller. The vulnerability was reported by Younes Dragoni of Nozomi Networks. Emerson has a new firmware version that mitigates the vulnerability. There is no indication that Dragoni has been provided an opportunity to verify the efficacy of the fix.

ICS-CERT reports that a relatively low-skilled attacker could remotely exploit the vulnerability to execute a denial of service attact.

Delta Advisory


This advisory describes three vulnerabilities in the Delta WPLSoft PLC programming software. The vulnerability was reported by Axt via the Zero Day Intitiative. The newest version of the software mitigates the vulnerability. There is no indication that Axt has been provided an opportunity to verify the efficacy of the fix.

The three reported vulnerabilities are:

• Stack-based buffer overflow - CVE-2018-7494;
• Heap-based buffer overflow - CVE-2018-7507; and
• Out-of-bounds write - CVE-2018-7509

ICS-CERT reports that a relatively low-skilled attacker could remotely exploit these vulnerabilities to allow remote code execution or cause the software the attacker is accessing to crash.

Siemens Advisory


This advisory describes a cryptographic vulnerability in the Siemens SIMATIC Industrial PCs. This is a 3rd party vulnerability in RSA key generation allowing for a potential ROCA attack. The vulnerability is being self-reported by Siemens. Siemens has produced firmware updates that mitigate the vulnerability.

ICS-CERT reports that an uncharacterized attacker [probably pretty skilled IMO] could remotely exploit the vulnerability to conduct cryptographic attacks against the key material.

NOTE: This is going to be a widespread vulnerability, potentially affecting any control system using Infineon’s Trusted Platform Module for the generation of RSA keys. It is also another vulnerability that it would have been helpful if ICS-CERT had published an alert on the topic last fall.

SIMATIC Update


This update provides additional information on an advisory that was was originally published on May 9th, 2017 and updated on June 15, 2017,on July 25th, 2017, on August 17th, 2017, on October 10th, on November 14thNovember 28th, and most recently January 18, 2018. The update adds five new vulnerabilities to the advisory:

• Improper restrictions of operations within the bounds of a memory buffer (3) - CVE-2017-12818, CVE-2017-12820, and CVE-2017-12821;
• Security features - CVE-2017-12819; and
• Improper access control - CVE-2017-12822

Industrial Products Update


This update provides additional information on an advisory that was originally published on December 5th, 2017 and updated on December 19th, 2017 and again on January 23rd, 2018. The new information includes new affected version data and mitigation links for:

• SIMATIC ET 200MP IM155-5 PN ST: All versions prior to V4.1;
• SIMOTION P V4.4 and V4.5: All versions prior to V4.5 HF5;
• DK Standard Ethernet Controller: All versions prior to V4.1.1 Patch 05; and
• EK-ERTEC 200 PN IO: All versions prior to V4.5

PROFINET 1 Update


This update provides additional information on an advisory that was originally published on May 9th, 2017 and updated on June 15, 2017,on July 25th, 2017, on August 17th, 2017, on October 10th, 2017, November 14th, 2017, and most recently on January 23rd, 2018. The update provides updated affected version information and mitigation links for:

• SIMATIC WinCC flexible 2008: All versions prior to flexible 2008 SP5

PROFINET 2 Update


This update provides additional information on an advisory that was originally published on May 9th, 2017 and updated on June 15, 2017,on July 25th, 2017, on August 17th, 2017, on October 10th, on November 14th,  November 28th, 2017, and most recently January 18th, 2018, and most recently on January 25th, 2018. The new information includes new affected version data and mitigation links for:

• SIMATIC ET 200MP-IMI55-5 PN ST: All versions prior to V4.1

Ruggedcom Update


This update provides additional information on an advisory that was was originally published on September 28th, 2017, and updated on October 17th, 2017. The new information adds corrected version information and mitigation links for:

• SCALANCE XR-500/XM-400: All versions between v6.1 and 6.1.1; and
• SCALANCE XB-200/XC-200/XP-200/XR300-WG: All versions between v3.0 and v3.0.2

 