Showing posts with label Medtronics. Show all posts
Showing posts with label Medtronics. Show all posts

Saturday, March 16, 2019

Public ICS Disclosures – Week of 03-09-19


This week we have five vendor notifications for products from Siemens, PEPPERL+FUCHS, and Schneider(3) and four vendor updates of previously published advisories for products from Siemens(3) and Medtronics.

Siemens Advisory


Siemens published an advisory describing a mirror port isolation vulnerability in their SCALANCE X switches. The vulnerability is being self-reported. Siemens has provided generic workarounds to mitigate the vulnerability.

PEPPERL+FUCHS Advisory


VDE CERT published an advisory describing two vulnerabilities in the PEPPERL+FUCHS ecom mobile devices. The vulnerabilities were reported by Ben Seri and Gregory Vishnepolsky of Armis; the armis 2017 Blueborne disclosure includes exploits. PEPPERL+FUCHS points to (no links provided) OEM vendors for updates for some of the affected products.

Schneider Advisories


Schneider published an advisory describing an uncontrolled search path element vulnerability in their Pelco VideoXpert OpsCenter. The vulnerability was reported by Osama Radwan. Schneider has a new version that mitigates the vulnerability. There is no indication that Radwan has been provided an opportunity to verify the efficacy of the fix.

Schneider published an advisory describing an SQL injection vulnerability in their U.motion Builder software product. The vulnerability was reported by Julien Ahrens (RCE Security). Schneider recommends that customers stop using the their U.motion Builder software product as it is no longer supported.

Schneider published an advisory describing an improper check for unusual or exceptional conditions vulnerability in their Triconex TriStation Emulator. The vulnerability was reported by Tom Westenberg – Applied Risk. Schneider plans to have an update available in July and has provided generic workarounds to mitigate the vulnerability in the mean time.

Siemens Updates


Siemens published an update for their advisory on Spectre and Meltdown Vulnerabilities in Industrial Products. They added an updated solution for their SINUMERIK PCU. NCCIC-ICS is not expected to publish and update for their Meltdown/Spectre alert (ICS-ALERT-18-011-01) since the link in that Alert to the Siemens Industrial Products already takes one to this latest update.

Siemens published an update for their advisory on Foreshadow / L1 Terminal Fault Vulnerabilities in Industrial Products. They added an updated solution for their SINUMERIK PCU. NCCIC-ICS has not published any advisories or alerts about the Foreshadow vulnerabilities.

Siemens published an update for their advisory on Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP. They added 14 new CVE’s to the already lengthy list of CVE’s covered in the advisory. NCCIC-ICS has not published an advisories or alerts on this family of Linux vulnerabilities.

Medtronic Update


Medtronic published an update for their advisory on MiniMed™ Paradigm™ Insulin Pumps. They added:

• Two new affected devices available in the US; and
A link to the field safety notification letter issued in August, 2018.

The NCCIC-ICS advisory (ICSMA-18-219-02) was originally published on August 8th, 2018. I suspect that this will be updated in the coming week.

NOTE: It is interesting that the letter (dated August 7th, 2018; the date of the original advisory) includes the two affected devices that are being added to the advisory via this update. The original Medtronic advisory made special note that none of the affected devices were available for sale in the United States.

Wednesday, February 28, 2018

ICS-CERT Publishes 5 Advisories and 5 Siemens Updates


Yesterday the DHS ICS-CERT published two medical device security advisories for products from Philips and Medtronic. They published three industrial control system security advisories for products from Emerson, Delta Electronics and Siemens. They also updated five previously published control system security advisories for a variety of products from Siemens.

NOTE: The Siemens advisory and five updates were briefly mentioned here last week. There was another advisory and another update (both 3rd party vendor problems affecting Siemens products) that Siemens announced at the same time that ICS-CERT has apparently decided not to address.

ICS-CERT also recently announced a call for abstracts for the Spring 2018 meeting of the ICSJWG in Albuquerque, NM on April 10 - 12, 2018. Abstracts need to be submitted by March 13th, 2018.

Philips Advisory


This advisory describes a relatively large number of vulnerabilities in the Philips Intellispace Portal ISP visualization and image analysis system. The vulnerabilities are apparently being self-reported. There is no report about these vulnerabilities on the FDA medical device safety page. Philips will be issuing an updated version in the coming months to mitigate the vulnerabilities.

NOTE: Apparently at least some of these vulnerabilities are 3rd party vendor issues that have seen publicly available exploits in other products.

The 35 reported vulnerabilities include:

• Improper input validation (13) - CVE-2018-5474, CVE-2017-0143, CVE-2017-0144, CVE-2017-0145, CVE-2017-0146, CVE-2017-0148, CVE-2017-0272, CVE-2017-0277, CVE-2017-0278, CVE-2017-0279, CVE-2017-0269, CVE-2017-0273, and CVE-2017-0280;
• Information exposure (8) - CVE-2017-0147, CVE-2017-0267, CVE-2017-0268, CVE-2017-0270, CVE-2017-0271, CVE-2017-0274, CVE-2017-0275, and CVE-2017-0276;
• Permissions, privileges and access controls (4) - CVE-2018-5472, CVE-2018-5468, CVE-2017-0199, and CVE-2005-1794;
• Unquoted search path element - CVE-2018-5470;
• Left over debug code - CVE-2018-5454; and
Cryptographic issues (8) - CVE-2018-5458, CVE-2018-5462, CVE-2018-5464, CVE-2018-5466, CVE-2011-3389, CVE-2004-2761, CVE-2014-3566, and CVE-2016-2183

ICS-CERT reports that an uncharacterized attacker could remotely exploit these vulnerabilities  to gain unauthorized access to sensitive information, perform man-in-the-middle attacks, create denial of service conditions, or execute arbitrary code.

Medtronic Advisory


This advisory describes two vulnerabilities in the Medtronic 2090 CareLink Programmers. The vulnerabilities were reported by Billy Rios and Jonathan Butts of Whitescope LLC. There is no report about these vulnerabilities on the FDA medical device safety page. Medtronics has identified compensating controls that mitigate the vulnerability. There is no indication that the researchers have been provided an opportunity to verify the efficacy of the fix.

The two reported vulnerabilities are:

• Strong password in a recoverable format - CVE-2018-5446; and
• Relative path traversal - CVE-2018-5448

ICS-CERT reports that an uncharacterized attacker with access to a CareLink Programmer could exploit the vulnerability to obtain per-product credentials to the software deployment network. These credentials grant access to the software deployment network, but access is limited to read-only versions of device software applications. No write capability exists with the credentials.

Emerson Advisory


This advisory describes a stack-based buffer overflow vulnerability in the Emerson ControlWave Micro Process Automation Controller. The vulnerability was reported by Younes Dragoni of Nozomi Networks. Emerson has a new firmware version that mitigates the vulnerability. There is no indication that Dragoni has been provided an opportunity to verify the efficacy of the fix.

ICS-CERT reports that a relatively low-skilled attacker could remotely exploit the vulnerability to execute a denial of service attact.

Delta Advisory


This advisory describes three vulnerabilities in the Delta WPLSoft PLC programming software. The vulnerability was reported by Axt via the Zero Day Intitiative. The newest version of the software mitigates the vulnerability. There is no indication that Axt has been provided an opportunity to verify the efficacy of the fix.

The three reported vulnerabilities are:

• Stack-based buffer overflow - CVE-2018-7494;
• Heap-based buffer overflow - CVE-2018-7507; and
• Out-of-bounds write - CVE-2018-7509

ICS-CERT reports that a relatively low-skilled attacker could remotely exploit these vulnerabilities to allow remote code execution or cause the software the attacker is accessing to crash.

Siemens Advisory


This advisory describes a cryptographic vulnerability in the Siemens SIMATIC Industrial PCs. This is a 3rd party vulnerability in RSA key generation allowing for a potential ROCA attack. The vulnerability is being self-reported by Siemens. Siemens has produced firmware updates that mitigate the vulnerability.

ICS-CERT reports that an uncharacterized attacker [probably pretty skilled IMO] could remotely exploit the vulnerability to conduct cryptographic attacks against the key material.

NOTE: This is going to be a widespread vulnerability, potentially affecting any control system using Infineon’s Trusted Platform Module for the generation of RSA keys. It is also another vulnerability that it would have been helpful if ICS-CERT had published an alert on the topic last fall.

SIMATIC Update


This update provides additional information on an advisory that was was originally published on May 9th, 2017 and updated on June 15, 2017,on July 25th, 2017, on August 17th, 2017, on October 10th, on November 14thNovember 28th, and most recently January 18, 2018. The update adds five new vulnerabilities to the advisory:

• Improper restrictions of operations within the bounds of a memory buffer (3) - CVE-2017-12818, CVE-2017-12820, and CVE-2017-12821;
• Security features - CVE-2017-12819; and
• Improper access control - CVE-2017-12822

Industrial Products Update


This update provides additional information on an advisory that was originally published on December 5th, 2017 and updated on December 19th, 2017 and again on January 23rd, 2018. The new information includes new affected version data and mitigation links for:

• SIMATIC ET 200MP IM155-5 PN ST: All versions prior to V4.1;
• SIMOTION P V4.4 and V4.5: All versions prior to V4.5 HF5;
• DK Standard Ethernet Controller: All versions prior to V4.1.1 Patch 05; and
• EK-ERTEC 200 PN IO: All versions prior to V4.5

PROFINET 1 Update


This update provides additional information on an advisory that was originally published on May 9th, 2017 and updated on June 15, 2017,on July 25th, 2017, on August 17th, 2017, on October 10th, 2017, November 14th, 2017, and most recently on January 23rd, 2018. The update provides updated affected version information and mitigation links for:

• SIMATIC WinCC flexible 2008: All versions prior to flexible 2008 SP5

PROFINET 2 Update


This update provides additional information on an advisory that was originally published on May 9th, 2017 and updated on June 15, 2017,on July 25th, 2017, on August 17th, 2017, on October 10th, on November 14th,  November 28th, 2017, and most recently January 18th, 2018, and most recently on January 25th, 2018. The new information includes new affected version data and mitigation links for:

• SIMATIC ET 200MP-IMI55-5 PN ST: All versions prior to V4.1

Ruggedcom Update


This update provides additional information on an advisory that was was originally published on September 28th, 2017, and updated on October 17th, 2017. The new information adds corrected version information and mitigation links for:

• SCALANCE XR-500/XM-400: All versions between v6.1 and 6.1.1; and
• SCALANCE XB-200/XC-200/XP-200/XR300-WG: All versions between v3.0 and v3.0.2

 
/* Use this with templates/template-twocol.html */