Friday, November 15, 2019

6 Advisories and 2 Updates Published – 11-14-19


Yesterday the CISA NCCIC-ICS published five control system security advisories for products from ABB, Omron and Siemens (3); and one medical device security advisory for products from Philips. They also updated two previously published advisories for products from Siemens.

ABB Advisory


This advisory describes an authentication bypass using an alternate path or channel vulnerability in the ABB Power Generation Information Manager (PGIM) and Plant Connect monitoring platforms. This vulnerability was reported by Rikard Bodforss. ABB reports that PGIM will transition to a limited support phase in January 2020, and Plant Connect is already obsolete.

NCCIC reports that a relatively low-skilled attacker could remotely exploit the vulnerability to allow a remote attacker to bypass authentication and extract credentials from the device.

NOTE: I briefly reported on this vulnerability earlier this month.

Omron Advisory


This advisory describes a use of obsolete function vulnerability in the Omron CX-Supervisor. The vulnerability was reported by Michael DePlante of the Zero Day Initiative. Omron has a new version that mitigates the vulnerability. There is no indication that DePlante has been provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit this vulnerability to result in information disclosure, total compromise of the system, and system unavailability.

Desigo PX Advisory


This advisory describes an external control of assumed immutable web parameter vulnerability in the Siemens Desigo PX automation controllers. The vulnerability was reported by Gjoko “LiquidWorm” Krstic from Zero Science Lab. Siemens has updates that mitigate the vulnerability. There is no indication that Kristic has been provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit this vulnerability to allow an attacker to cause a denial-of-service condition on the device’s web server, requiring a reboot to recover the web interface.

S7-1200 Advisory


This advisory describes an exposed dangerous method or function vulnerability in the Siemens S7-1200 CPU. The vulnerability was reported by Ali Abbasi from Ruhr University of Bochum. Siemens has provided generic workarounds for this vulnerability.

NCCIC-ICS reports that a relatively low-skilled attacker with uncharacterized access could exploit this vulnerability to  expose additional diagnostic functionality to an attacker with physical access to the UART interface during boot process. The Siemens advisory notes that the attacker must have physical access to the UART interface during boot process to exploit the vulnerability (feature).
NOTE: I briefly discussed this vulnerability last weekend.

Mentor Nucleus Advisory


This advisory describes an improper input validation vulnerability in the Siemens Mentor Nucleus Networking Module. The vulnerability was reported by Armis. Siemens has updates that mitigate the vulnerability. There is no indication that Armis was provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reports that a relatively low-skilled attacker with uncharacterized access could exploit the vulnerability to allow an attacker to affect the integrity and availability of the device. According to the Siemens advisory adjacent network access (but no authentication and no user interaction) is required to exploit the vulnerability

Philips Advisory


This advisory describes an inadequate encryption strength vulnerability in the Philips IntelliBridge EC40 and EC80 data transfer devices. The vulnerability was reported by The Medical Technology Solutions team of NewYork-Presbyterian Hospital. Philips has provided generic workarounds while developing formal mitigation.

NCCIC-ICS reports that a relatively low-skilled attacker with uncharacterized access could exploit this vulnerability to allow an attacker unauthorized access to the IntelliBridge EC40/80 hub and may allow access to execute software, modify system configuration, or view/update files, including unidentifiable patient data.

PROFINET Update


This update provides additional information on an advisory that was originally published on October 10th, 2019. The new information includes new affected version information and mitigation measures for:

• SINAMICS S120 V4.7;
• SINAMICS S150;
• SINAMICS G130 V4.7;
• SINAMICS G150; and
• SINAMICS SL150 V4.7

Industrial Products Update


This update provides additional information on an advisory that was was originally published on September 10th, 2019 and most recently updated on October 8th, 2019. The new information includes:

• Updated version information and mitigation link for SIMATIC MV500; and
• Removed SIMATIC RF166C from affected products.

Other Siemens Updates


On Tuesday Siemens also published two other advisory updates that have not yet been addressed by NCCIC-ICS, nor do I expect them to be addressed as the underlying vulnerabilities have not been reported by NCCIC-ICS. I will report on them tomorrow.

Tuesday, July 30, 2019

2 Advisories and 1 Alert Published – 07-30-19


Today the DHS NCCIC-ICS published a control system security alert for CAN bus network implementation in avionics and two control system security advisories for products from Prima Systems ad Wind River.

CAN Bus Alert


This alert briefly describes a public report about insecure implementation of CAN bus networks affecting aircraft. The report was published by Patrick Kiley of Rapid7.

Prima Systems Advisory


This advisory describes nine vulnerabilities in the Prima Systems FlexAir access control platform. The vulnerabilities were reported by Gjoko Krstic of Applied Risk. Prima Systems has a new version that mitigates the vulnerabilities. There is no indication that Krstic has been provided an opportunity to verify the efficacy of the fix.

The nine reported vulnerabilities are:

OS command injection - CVE-2019-7670;
Unrestricted upload of file with dangerous type (2) - CVE-2019-7669 and CVE-2019-9189;
Cross-site request forgery - CVE-2019-7281;
Small space of random values - CVE-2019-7280;
Cross-site scripting - CVE-2019-7671;
Exposure of a backup file to an unauthorized control sphere - CVE-2019-7667;
Improper authentication - CVE-2019-7666; and
Use of hard-coded credentials - CVE-2019-7672

NOTE 1: NCCIC-ICS does not include a default credentials vulnerability, CVE-2019-7668, reported by Krstic.

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit these vulnerabilities to allow an attacker to execute commands directly on the operating system, upload malicious files, perform actions with administrative privileges, execute arbitrary code in a user’s browser, discover login credentials, bypass normal authentication, and have full system access.

NOTE 2: I briefly described the Rapid7 report back in May.

Wind River Advisory


This advisory describes eleven vulnerabilities in the Wind River VxWorks operating system. The vulnerabilities were reported by Armis researchers Gregory Vishnepolsky, Dor Zusman, and Ben Seri. Wind River has patches to mitigate the vulnerabilities. There is no indication that the researchers have been provided an opportunity to verify the efficacy of the fix.

The eleven reported vulnerabilities are:

Stack-based buffer overflow - CVE-2019-12256;
Heap-based buffer overflow - CVE-2019-12257;
Integer underflow - CVE-2019-12255;
Improper restrictions of operations within the bounds of a memory buffer (2) - CVE-2019-12260 and CVE-2019-12261;
Race condition - CVE-2019-12263;
Argument injection or modification (4) - CVE-2019-12258, CVE-2019-12262, CVE-2019-12264 and CVE-2019-12265; and
Null pointer dereference - CVE-2019-12259;

Since the affected operating systems are used in a large number of IoT and ICS systems we can expect advisories from affected vendors implementing the Wind River mitigations measures. The NCCIC-ICS advisory already lists 2 vendor advisories and the Armis report adds a third. The three vendor advisories available to date include:

Rockwell,
Xerox, and

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit these vulnerabilities to allow remote code execution.

Saturday, March 16, 2019

Public ICS Disclosures – Week of 03-09-19


This week we have five vendor notifications for products from Siemens, PEPPERL+FUCHS, and Schneider(3) and four vendor updates of previously published advisories for products from Siemens(3) and Medtronics.

Siemens Advisory


Siemens published an advisory describing a mirror port isolation vulnerability in their SCALANCE X switches. The vulnerability is being self-reported. Siemens has provided generic workarounds to mitigate the vulnerability.

PEPPERL+FUCHS Advisory


VDE CERT published an advisory describing two vulnerabilities in the PEPPERL+FUCHS ecom mobile devices. The vulnerabilities were reported by Ben Seri and Gregory Vishnepolsky of Armis; the armis 2017 Blueborne disclosure includes exploits. PEPPERL+FUCHS points to (no links provided) OEM vendors for updates for some of the affected products.

Schneider Advisories


Schneider published an advisory describing an uncontrolled search path element vulnerability in their Pelco VideoXpert OpsCenter. The vulnerability was reported by Osama Radwan. Schneider has a new version that mitigates the vulnerability. There is no indication that Radwan has been provided an opportunity to verify the efficacy of the fix.

Schneider published an advisory describing an SQL injection vulnerability in their U.motion Builder software product. The vulnerability was reported by Julien Ahrens (RCE Security). Schneider recommends that customers stop using the their U.motion Builder software product as it is no longer supported.

Schneider published an advisory describing an improper check for unusual or exceptional conditions vulnerability in their Triconex TriStation Emulator. The vulnerability was reported by Tom Westenberg – Applied Risk. Schneider plans to have an update available in July and has provided generic workarounds to mitigate the vulnerability in the mean time.

Siemens Updates


Siemens published an update for their advisory on Spectre and Meltdown Vulnerabilities in Industrial Products. They added an updated solution for their SINUMERIK PCU. NCCIC-ICS is not expected to publish and update for their Meltdown/Spectre alert (ICS-ALERT-18-011-01) since the link in that Alert to the Siemens Industrial Products already takes one to this latest update.

Siemens published an update for their advisory on Foreshadow / L1 Terminal Fault Vulnerabilities in Industrial Products. They added an updated solution for their SINUMERIK PCU. NCCIC-ICS has not published any advisories or alerts about the Foreshadow vulnerabilities.

Siemens published an update for their advisory on Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP. They added 14 new CVE’s to the already lengthy list of CVE’s covered in the advisory. NCCIC-ICS has not published an advisories or alerts on this family of Linux vulnerabilities.

Medtronic Update


Medtronic published an update for their advisory on MiniMed™ Paradigm™ Insulin Pumps. They added:

• Two new affected devices available in the US; and
A link to the field safety notification letter issued in August, 2018.

The NCCIC-ICS advisory (ICSMA-18-219-02) was originally published on August 8th, 2018. I suspect that this will be updated in the coming week.

NOTE: It is interesting that the letter (dated August 7th, 2018; the date of the original advisory) includes the two affected devices that are being added to the advisory via this update. The original Medtronic advisory made special note that none of the affected devices were available for sale in the United States.

 