Saturday, March 16, 2024

CRS Reports – Week of 3-9-24 – Change Healthcare

This week the Congressional Research Service (CRS) published a report on “The Change Healthcare Cyberattack and Response Considerations for Policymakers”. The report provides a brief look at the BlackCat ransomware attack on Change Healthcare and the wide spread consequences of that attack. It concludes by introducing a new term to cybersecurity considerations: ‘information parity’.

The author makes the point that following the FBI takedown of the BlackCat infrastructure, the ransomware organization re-grouped and encouraged its affiliates to attack hospitals and other healthcare organizations. While a number of hospitals were successfully attacked, the victim that caused the most disruption and political notice was the attack on Change Healthcare. Almost certainly, that disruption was because the immediate response to the attack was to shut down all cyber systems to stop the potential spread of the ransomware. As the report notes there is a similarity here to the attack on Colonial Pipeline: “Both attacks began with ransomware, led the victim to disconnect systems thereby causing operational disruptions, which resulted in physical consequences.” The physical consequences here were to interfere with the delivery of prescriptions to many people across the country.

In addition to a discussion about policy issued revealed by this attack, the report looks at three information parity (in this case government agencies having access to the same level of details about the situation in making agency decisions) problems raised by this incident:

• Coordination of offensive and defensive actions,

• Knowledge of conditions in decision making, and

• Information sharing reach.

Thursday, August 29, 2019

2 Advisories Published – 08-29-19


Today the DHS NCCIC-ICS published two medical device control system security advisories for products from Philips and Change Healthcare.

Philips Advisory


This advisory describes a use of obsolete function vulnerability in the Philips HDI 4000 Ultrasound Systems. The vulnerability was reported by Check Point. Philips has provided generic measure to mitigate the vulnerability and reports that the devices reached end-of-support in December of 2013. There is no indication that the researchers have been provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reports that an uncharacterized attacker with access to the local subnet could use publicly available exploits to exploit the vulnerability to lead to exposure of ultrasound images (breaches of confidentiality) and compromised image integrity.

Change Healthcare Advisory


This advisory describes an incorrect default permissions vulnerability in the Change Healthcare Cardiology Devices. The vulnerability was reported by Alfonso Powers and Bradley Shubin of Asante Information Security. Change Healthcare has a patch to mitigate the vulnerability. There is no indication that the researchers have been provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reports that an uncharacterized attacker with authenticated access can exploit the vulnerability to allow a locally authenticated user to insert specially crafted files that could result in arbitrary code execution.

Friday, October 5, 2018

ICS Advisory and 2 Medical Device Advisories


Yesterday the DHS NCCIC-ICS published a controls system security advisory for products from WECON and two medical device security advisories for products from Change Healthcare and Carestream.

WECON Advisory


This advisory describes four vulnerabilities in the WECON PI Studio, a HMI project programmer. The vulnerabilities were reported by Mat Powell and Natnael Samson (Natti) via the Zero Day Initiative. WECON is working on mitigation measures.

The four reported vulnerabilities are:

• Stack-based buffer overflow - CVE-2018-14818;
• Out-of-bounds write - CVE-2018-14810;
• Information exposure through XML external entity reference - CVE-2018-17889; and
• Out-of-bounds read - CVE-2018-14814

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit these vulnerabilities to allow remote code execution, execution of code in the context of an administrator, read past the end of an allocated object or allow an attacker to disclose sensitive information under the context of administrator.

Change Healthcare Advisory


This advisory describes an information exposure through error message vulnerability in the Change Healthcare PeerVue Web Server. The vulnerability was reported by Dan Regalado of Zingbox. Change Healthcare has a patch available to mitigate the vulnerability. There is no indication that Regalado has been provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reports that a relatively low-skilled attacker on an adjacent network could exploit the vulnerability to allow an attacker to obtain technical information about the PeerVue Web Server, allowing an attacker to target a system for attack.

Carestream Advisory


This advisory describes an information exposure through an error message vulnerability in the Carestream Vue RIS, a web-based radiology information system. The vulnerability was reported by Dan Regalado of Zingbox. Carestream has a new version that mitigates the vulnerability and has provided workarounds. There is no indication that Regalado has been provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reports that an uncharacterized attacker with access to the network can exploit the vulnerability to passively read traffic.

NOTE: It is always interesting to see a researcher who has found an unusual vulnerability in one system to then look for the same type vulnerability in other related systems. It makes me wonder if developers reading these advisories (and of course they do, right?) ask themselves if their systems have the same vulnerability.

 