Tuesday, October 26, 2021

Review - 1 Advisory Published – 10-26-21

Today, CISA’s NCCIC-ICS published a control system security advisory for products from Fuji Electric.

Fuji Advisory - This advisory describes six vulnerabilities in the Fuji Tellus Lite V-Simulator, and V-Server Lite products.

For more details about the advisory, including my discussion about how 20 vulnerabilities reported by kimiya via the Zero Day Initiative became 6 vulnerabilities in today’s advisory, see my article at CFSN Detailed Analysis - https://patrickcoyle.substack.com/p/1-advisory-published-10-26-21 - subscription required. [Link added - 10-26-21, 22:50 EDT]

Saturday, September 12, 2020

Public ICS Disclosure – Week of 9-2-20

We have eight vendor notifications about the CodeMeter vulnerabilities reported earlier this week by NCCIC-ICS from Phoenix Contact, PEPPERL+FUCHS, WAGO, ABB, and Pilz. We also have four vendor notification from Schneider, Moxa, Medtronic, and BD. There is a vendor update from Mitsubishi. We have a researcher report of 0-day vulnerabilities for products from Fuji Electric.

CodeMeter Advisories

Phoenix Contact published an advisory for the CodeMeter vulnerabilities. They listed their affected products and announced a new version of their Activation Wizard that mitigates the vulnerabilities.

VDE-CERT published an advisory for the CodeMeter vulnerabilities in products from PEPPERL+FUCHS. It provides a list of affected products and recommends implementing the WIBU Systems update.

VDE-CERT published an advisory for the CodeMeter vulnerabilities in products from WAGO. It reports that the e!COCKPIT engineering software is bundled with the CodeMeter software. VDE-CERT notes that WAGO will update their e!COCKPIT setup routine later this year.

ABB published four CodeMeter advisories for the following products:

• General information,

• AC 800PEC platform,

• Ability™ Operations Data Management zenon, and

• ABB Drives applications

Pilz published an advisory for the CodeMeter vulnerabilities. It provides a list of affected products and recommends using the current version of CodeMeter.

Schneider Advisory

Schneider published an advisory describing five vulnerabilities in their SCADAPack remote connect and security administrator applications. The vulnerabilities were reported by Amir Preminger of Claroty. Schneider has new versions that mitigate the vulnerabilities. There is no indication that Preminger has been provided an opportunity to verify the efficacy of the fix.

The five reported vulnerabilities are:

• Deserialization of untrusted data - CVE-2020-7528 and CVE-2020-7532,

• Path transversal - CVE-2020-7529,

• Improper authorization - CVE-2020-7530, and

• Improper access control - CVE-2020-7531

Moxa Advisory

Moxa published an advisory for the BootHole vulnerability. Moxa reports that none of its products are affected.

Medtronic Advisory

Medtronic published an advisory describing the SweynTooth vulnerabilities in a number of their products. Medtronic reports that they remediated these vulnerabilities when they did their software update in June 2020.

BD Advisory

BD published an advisory describing the SigRed vulnerabilities in a number of their products. BD recommends ensuring that the appropriate Microsoft® patches have been applied.

Mitsubishi Update

Mitsubishi published an update for their MC Works advisory that was originally published on June 18th, 2020. The new information includes links for security patches for MC Works64 Version 4.00A - 4.02C.

Fuji Electric Reports

Kimiya published 14 reports (ZDI-20-1103 thru ZDI-20-1117) of vulnerabilities in the Fuji Electric Tellus Lite product. The vulnerabilities were reported to ‘ICS-CERT’ (presumably, NCCIC-ICS) by the Zero Day Initiative back in April.

The vulnerabilities include:

• Stack-based buffer overflow,

• Out-of-bounds write, and

• Out-of-bounds read

Tuesday, April 7, 2020

5 Advisories and 1 Update Published


Today the CISA NCCIC-ICS published five control system security advisories for products from KUKA, Fuji Electric, HMS Networks, GE Digital and Advantech. They also updated an advisory for products from Synergy.

KUKA Advisory


This advisory describes an improper enforcement of message integrity in a communications channel vulnerability in the KUKA Sim Pro. The vulnerability was reported by Federico Maggi of Trend Micro. KUKA has an upgrade that mitigates the vulnerability. There is no indication that Maggi has been provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit the vulnerability to result in a loss of integrity in external 3D models fetched from remote servers. When tested on real machines, this effect is unpredictable.

Fuji Advisory


This advisory describes a heap-based buffer overflow vulnerability in the Fuji V-Server Lite. The vulnerability was reported by kimiya via the Zero Day Initiative. Fuji has a new version that mitigates the vulnerability. There is no indication that kimiya has been provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reported that a relatively low-skilled attacker could remotely exploit the vulnerability to allow a remote attacker to gain elevated privileges for remote code execution.

HMS Advisory


This advisory describes a cross-site scripting vulnerability in the HMS eWON Flexy and Cosy. The vulnerability was reported by Ander Martínez of Titanium Industrial Security. HMS has a firmware update that mitigates the vulnerability. There is no indication that Martinez has been provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reports that an uncharacterized attacker could remotely exploit this vulnerability to initiate a password change.

NOTE: I briefly discussed this vulnerability back in February.

GE Advisory


This advisory describes an improper privilege management vulnerability in the GE Digital CIMPLICITY HMI/SCADA product. The vulnerability was reported by Sharon Brizinov of Claroty. GE has a new version that mitigates the vulnerability. There is no indication that Brizinov has been provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reports that a relatively low-skilled attacker with uncharacterized access could exploit the vulnerability to allow an adversary to modify the systemwide CIMPLICITY configuration, leading to the arbitrary execution of code.

NOTE: I briefly discussed this vulnerability last weekend.

Advantech Advisory


This advisory describes eight vulnerabilities in the Advantech WebAccess/NMS network management system. The vulnerability was reported by rgod of 9sg via ZDI. Advantech has a new version that mitigates the vulnerability. There is no indication that rgod was provided an opportunity to verify the efficacy of the fix.

The eight reported vulnerabilities are:

• Unrestricted upload of file with dangerous type - CVE-2020-10621;
• SQL injection (2) - CVE-2020-10617 and CVE-2020-10623;
• Relative path traversal (2) - CVE-2020-10619 and CVE-2020-10631;
• Missing authentication for critical function - CVE-2020-10625;
• Improper restriction of XML external entity reference -CVE-2020-10629; and
• OS command injection - CVE-2020-10603

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit these vulnerabilities to allow an attacker to gain remote code execution, upload files, delete files, cause a denial-of-service condition, and create an admin account for the application.

Synergy Update


This update provides new information on an advisory that was originally published on February 11th, 2020. The new information includes:

• Four new vulnerabilities:
◦ Missing authentication for critical function - CVE-2019-16879;
◦ Improper check for unusual or exceptional conditions - CVE-2020-7800;
◦ Exposure of sensitive information to an unauthorized actor - CVE-2020-7801; and
◦ Incorrect default permissions - CVE-2020-7802
• Links to three associated advisories from SSS (here, here and here)

Tuesday, March 17, 2020

1 Advisory Published – 3-17-20


Today the CISA NCCIC-ICS published one control system security advisory for products from Delta Electronics.

Delta Advisory


The advisory describes two vulnerabilities in the Delta Industrial Automation CNCSoft ScreenEditor. The vulnerability was reported by Natnael Samson (@NattiSamson) and kimiya, working with the Zero Day Initiative. Delta has a new version that mitigates the vulnerabilities. There is no indication that the researchers have been provided an opportunity to verify the efficacy of the fix.

The two reported vulnerabilities are:

• Stack-based buffer overflow - CVE-2020-7002; and
• Out-of-bounds read - CVE-2020-6976

NCCIC-ICS reports that a relatively low-skilled attacker with uncharacterized access could exploit the vulnerabilities to cause buffer overflow conditions that may allow information disclosure, remote code execution, or crash the application. According to the ZDI advisories (here, here and here) the vulnerabilities are remotely exploitable.

Commentary


The two different ZDI advisories for the buffer overflow vulnerability show slightly different descriptions of the vulnerability. Both describe parsing problems in DBP files. The kimiya advisory appears to be slightly more generic where the Samson advisory specifies that the problem lies in parsing the GifName information in DPB files. There is a possibility that there are two separate vulnerabilities here. This is where it would be helpful to have the researchers verify the efficacy of the fix. We could have a situation here where the more specific vulnerability was fixed, but the more generic problem remains.

Friday, November 8, 2019

4 Advisories and 1 Update Published – 11-07-19


Yesterday the CISA NCCIC-ICS published two control system security advisories for products from Fuji Electric and Mitsubishi Electric; and two medical device security advisories for products from Medtronic (2). The also updated a previously published medical device advisory for products from Philips.

Fuji Advisory


This advisory describes a heap-based buffer overflow vulnerability in the Fuji V-Server. The vulnerability was reported by kimiya of 9SG via the Zero Day Initiative. Fuji has a new version that mitigates the vulnerability. There is no indication that kimiya has been provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reports that a relatively low-skilled attacker with uncharacterized access could exploit the vulnerability to crash the device being accessed; several heap-based buffer overflows have been identified.

Mitsubishi Advisory


This advisory describes an uncontrolled resource consumption vulnerability in the Mitsubishi MELSEC-Q Series and MELSEC-L Series CPU Modules. The vulnerability was reported by Tri Quach of Amazon’s Customer Fulfillment Technology Security (CFTS) group. Mitsubishi has a new firmware version that mitigates the vulnerability. There is no indication that Tri has been provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit this vulnerability to prevent the FTP client from connecting to the FTP server on MELSEC-Q Series and MELSEC-L Series CPU module. Only FTP server function is affected by this vulnerability.

Medtronic Advisory #1


This advisory describes two RFID security vulnerabilities in the Medtronic Valleylab energy and electrosurgery products. The vulnerabilities are self-reported. Medtronic has a patch available to mitigate the vulnerabilities.

The two reported vulnerabilities are:

• Improper authentication - CVE-2019-13531; and
• Protection mechanism failure - CVE-2019-13535

NCCIC-ICS reports that a relatively low-skilled attacker with uncharacterized access could exploit the vulnerabilities to allow an attacker to connect inauthentic instruments to the affected products by spoofing RFID security mechanisms. This may lead to a loss of performance integrity and platform availability due to incorrect identification of instrument and associated parameters.

Medtronic Advisory #2


This advisory describes four vulnerabilities in the Medtronic Valleylab energy products. The vulnerabilities are self-reported. Medtronic has patches available to mitigate the vulnerability.

The four reported vulnerabilities are:

• Use of hard-coded credentials - CVE-2019-13543;
• Reversible one-way hash - CVE-2019-13539; and
• Improper input validation (2) - CVE-2019-3464, and CVE-2019-3463.

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit these vulnerabilities to  allow an attacker to overwrite files or remotely execute code, resulting in a remote, non-root shell on the affected products. By default, the network connections on these devices are disabled. Additionally, the Ethernet port is disabled upon reboot. However, it is known that network connectivity is often enabled.

Philips Update


This update provides new information for and advisory that was originally reported on April 30th, 2019.
The new information includes:

• Revised (increased) overall CVSS score;
• Information exposure vulnerability added;
• Added Tasy WEbPortal to affected product list;
• Added Trabalho Médico IT Department as a vulnerability reporter; and
• Reported that a new version mitigates the vulnerabilities.

Tuesday, September 10, 2019

6 Advisories and 3 Updates Published – 09-10-19


The DHS NCCIC-ICS published six control system security advisories for products from OSIsoft, Siemens (4), and Delta Electronics. They also updated two previously published advisories for products from Siemens and an alert from Mitsubishi Electric Europe.

OSIsoft Advisory


This advisory describes an integer overflow or wraparound vulnerability in the OSIsoft PI SQL Client. The vulnerability is self-reported. OSIsoft has a new version that mitigates the vulnerability.

NCCIC-ICS reports that an uncharacterized attacker could remotely exploit the vulnerability to allow remote code execution or cause a denial of service, resulting in disclosure, deletion, or modification of information.

SIMATIC Advisory


This advisory describes an improper input validation vulnerability in the Siemens SIMATIC TDC CP51M1 multiprocessor automation system. The vulnerability is self-reported. Siemens has a new version that mitigates the vulnerability.

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit the vulnerability to create a denial-of-service condition within UDP communication.

WirelessHart Gateway Advisory


This advisory describes a cross-site scripting vulnerability in the Siemens IE/WSN-PA Link WirelessHART Gateway. The vulnerability is self-reported. Siemens has provided generic mitigation measures for the vulnerability.

NCCIC-ICS reports that an uncharacterized attacker could remotely exploit the vulnerability to allow information disclosure, code execution, or denial-of-service.

Comment: Usually a vendor provides generic mitigation measures for a vulnerability when they are forced to disclose a vulnerability due to the disclosure process. With this being a self-disclosed vulnerability, Siemens was not forced to disclose this vulnerability with a generic mitigation. That takes a certain amount of integrity, but it does place some of their customers at an unusual level of risk. The generic mitigation measure is not unusual or even an unexpected requirement, but some customers will not have taken the standard precaution and are unlikely to implement it now.

Industrial Product Advisory


This advisory describes three vulnerabilities in the Siemens Industrial Products. The vulnerabilities were self-reported. Siemens has new versions that mitigate the vulnerabilities is some of the affected products.

The three reported vulnerabilities are:

• Integer overflow or wraparound - CVE-2019-11477;
• Uncontrolled resource consumption (2) - CVE-2019-11478, and CVE-2019-11479

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit the vulnerabilities to cause denial-of-service condition.

SINETPLAN Advisory


This advisory describes an improper authorization vulnerability in the Siemens Network Planner (SINETPLAN). The vulnerability is self-reported. Siemens has a new version that mitigates the vulnerability.

NCCIC-ICS reports that a relatively low-skilled attacker with uncharacterized access could exploit the vulnerability to allow information disclosure, code execution, and denial-of-service. The Siemens Advisory notes that the vulnerability can only be exploited “local users”.

Delta Electronics Advisory


This advisory describes three vulnerabilities in the Delta Electronics TPEditor. The vulnerabilities were reported by kimiya of 9sg Security Team vis the Zero Day Initiative. Delta has a new version that mitigates the vulnerabilities. There is no indication that the researchers have been provided an opportunity to verify the efficacy of the fix.

The three reported vulnerabilities are:

• Stack-based buffer overflow - CVE-2019-13540;
• Heap-based buffer overflow - CVE-2019-13536; and
• Out-of-bounds write - CVE-2019-13544

NCCIC-ICS reports that a relatively low-skilled attacker with uncharacterized access could exploit the vulnerabilities to allow information disclosure, remote code execution, or may crash the application.

PCS7 Update


This update provides new information on an advisory that was originally reported on July 9th, 2019 and last updated on August 13th, 2019. The new information includes updated version information and mitigation links for SIMATIC WinCC Runtime Professional V14 and V15.

WinCC Update


This update provides new information on an advisory that was originally reported on July 11th, 2019 and updated on August 13th, 2019.

Mitsubishi Update


This update provides new information on an alert that was originally published on August 13, 2019. The revised alert changes the name of the vendor to “Mitsubishi Electric Europe B.V.”.

Other Siemens Advisories


Today was disclosure Tuesday for Siemens. They published six advisories and three updates. Two of those advisories are for third-party vulnerabilities (DejaBlue and Urgent/11). The Urgent/11 advisory could be added to the NCCIC-ICS advisory on those vulnerabilities via an update on Thursday. To date, NCCIC-ICS has not addressed DejaBlue, so I suspect that this Siemens advisory will be ignored. The last advisory will probably be addressed by NCCIC-ICS on Thursday.

Tuesday, August 13, 2019

1 Alert, 3 Advisories and 4 Updates Published – 08-13-19


Today the DHS NCCIC-ICS published a control system security alert for products from Mitsubishi Electric; three control system security advisories for products from Siemens, OSIsoft, and Delta Industrial; and four control system advisory updates for products from Siemens.

Mitsubishi Alert


This alert describes a report of seven vulnerabilities in the Mitsubishi smartRTU and INEA ME-RTU. The vulnerabilities were reported (with exploit code) by Mark Cross (@xerubus) (NCCIC-ICS did provide the link to the report, a first). Cross disclosed the vulnerabilities to CISA and published the public disclosure under the 45-day disclosure policy.

The seven reported vulnerabilities are:

• OS command injection - CVE-2019-14931;
• Unauthenticated download of configuration file - CVE-2019-14927;
• Stored cross-site script - CVE-2019-14928;
• Use of hard-coded cryptographic keys - CVE-2019-14926;
• Hard-coded user passwords - CVE-2019-14930;
• Plaintext password storage - CVE-2019-14929; and
• Incorrect default permissions - CVE-2019-14925


Siemens Advisory


This advisory describes an uncontrolled resource consumption vulnerability in the Siemens SCALANCE X switches. The vulnerability was reported by Younes Dragoni from Nozomi Networks. Siemens has provided generic workarounds. There is no indication that Dragoni has been provided an opportunity to verity the efficacy of the fix.

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit the vulnerability to cause a denial-of-service condition.

OSIsoft Advisory


This advisory describes two vulnerabilities in the OSIsoft PI Web API. The vulnerabilities are self-reported. OSIsoft has an update to mitigate the vulnerability.

The two reported vulnerabilities are:

• Inclusion of sensitive information in log files - CVE-2019-13515; and
• Protection mechanism failure.

NCCIC-ICS reports that an uncharacterized attacker could remotely exploit the vulnerabilities to allow direct attacks against the product and disclose sensitive information.

Delta Advisory


This advisory describes two vulnerabilities in the Delta DOPSoft Human Machine Interface (HMI) editing software. The vulnerability was reported by kimiya of 9SG Security Team via the Zero Day Initiative. Delta has a new version that mitigates the vulnerabilities. There is no indication that kimiya has been provided an opportunity to verify the efficacy of the fix.

The two reported vulnerabilities are:

• Out-of-bounds read - CVE-2019-13513; and
• Use after free - CVE-2019-13514

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit these vulnerabilities to allow information disclosure, remote code execution, or crash of the application.

SIMATIC WinCC Update


This update provides additional information on an advisory that was originally reported on July 11th, 2019. The update provides new affected version information and mitigation links for:

• SIMATIC WinCC V7.3;
• SIMATIC PCS 7 V8.1, and
• SIMATIC WinCC Runtime Professional V14

Spectrum Power Update


This update provides additional information on an advisory that was originally reported on July 9th, 2019. The update provides corrected version information for Spectrum Power 5.

SIPROTEC Update


This update provides additional information on an advisory that was originally reported on July 9th, 2019. The update provides additional mitigation information.

SIMATIC PCS7 Update


This update provides additional information on an advisory that was originally reported on July 9th, 2019. The update provides corrected version information and mitigation links for:

• SIMATIC WinCC V7.3; and
• SIMATIC PCS 7 V8.1
NOTE: Siemens published an additional two advisories and two updates today that were not reported by NCCIC-ICS. They may be reported on Thursday, if not, I will report on them on Saturday.

Friday, August 2, 2019

6 Advisories Published – 08-01-19


Yesterday the DHS NCCIC-ICS published six control system advisories for products from Leão Consultoria e Desenvolvimento de Sistemas (LCDS), Rockwell, 3S (2), Fuji Electric and Advantech.

LCDS Advisory


This advisory describes two vulnerabilities in the LCDS LAquis SCADA software. The vulnerabilities were reported by Francis Provencher (PRL) via the Zero Day Initiative. LCDS has an update available that mitigates the vulnerability. There is no indication that Provencher has been provided an opportunity to verify the efficacy of the fix.

The two reported vulnerabilities are:

• Out-of-bounds read - CVE-2019-10994; and
• Type confusion - CVE-2019-10980


NCCIC-ICS reports that a relatively low-skilled attacker with uncharacterized access could exploit the vulnerability to allow an attacker to obtain confidential information or execute remote code.

Rockwell Advisory


This advisory describes two vulnerabilities in the Rockwell Arena Simulation Software. The vulnerabilities were reported by kimiya of 9SG Security Team via ZDI. Rockwell has a new version that mitigates the vulnerability. There is no indication that kimiya has been provided an opportunity to verify the efficacy of the fix.

• Use after free - CVE-2019-13510; and
• Information exposure - CVE-2019-13511

NCCIC-ICS reports that a relatively low-skilled attacker with uncharacterized access could exploit the vulnerabilities to allow an attacker to cause a current Arena session to fault or enter a denial-of-service (DoS) state, allowing the attacker to run arbitrary code.

First CODESYS Advisory


This advisory describes an insufficiently protected credentials vulnerability in the CmpUserMgr component of 3S CODESYS products. The vulnerability was reported by JunYoung Park. 3S will correct this vulnerability in a new version to be released in February. The 3S advisory strongly recommends activating and using encryption of online communication whenever possible.

NCCIC-ICS reports that a relatively low-skilled attacker with uncharacterized access could exploit this vulnerability to allow for an attacker with access to PLC traffic to obtain user credentials.

NOTE: Is it just me or is this advisory just a seven-month zero-day announcement?

Second CODESYS Advisory


This advisory describes two vulnerabilities in the CmpGateway component of the 3S CODESYS products. These vulnerabilities are self-reported. 3S has a new version that mitigates the vulenrabilities.

The two reported vulnerabilities are:

• Unverified ownership - CVE-2019-9010; and
• Uncontrolled memory allocation - CVE-2019-9012 

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit the vulnerabilities to allow a remote attacker to close existing communication channels or to take over an already established user session to send crafted packets to a PLC.

NOTE 1: There were six other advisories published by 3S at the same time as the two referenced in these two NCCIC-ICS advisories. I will address them this weekend.

NOTE 2: A reminder that the CODESYS operating system is used in a wide variety of devices and systems. These vulnerabilities will have widespread application. Few vendors are expected to publish updates referencing these vulnerabilities.

Fuji Advisory


This advisory describes and out-of-bounds read vulnerability in the Fuji  FRENIC Loader. The vulnerability was reported by kimiya of 9SG Security Team via ZDI. Fuji has a new version that mitigates the vulnerability. There is no indication that the kimiya has been provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reports that a relatively low-skilled attacker with uncharacterized access could exploit the vulnerability to allow information disclosure.

Advantech Advisory


This advisory describes an out-of-bounds write vulnerability in the Advantech WebAccess HMI Designer. The vulnerability was reported by Mat Powell via ZDI. Advantech has a new version that mitigates the vulnerability. There is no indication that Powell has been provided an opportunity to verify the efficacy of the fix.

Friday, June 7, 2019

Two Advisories Published – 06-06-19


This advisory describes two vulnerabilities in the Panasonic Control FPWIN Pro PLC programming software. The vulnerability was reported by kimiya of 9sg Security Team via the Zero Day Initiative. Panasonic has a new version that mitigates the vulnerability. There is no indication that kimiya has been provided an opportunity to verify the efficacy of the fix.

The two reported vulnerabilities are:

• Heap-based buffer overflow - CVE-2019-6530; and
• Type Confusion - CVE-2019-6532

NCCIC-ICS reports that a relatively low-skilled attacker with uncharacterized access could exploit the vulnerability to crash the device and allow remote code execution.

Optergy Advisory


This advisory describes eight vulnerabilities in the Optergy Proton/Enterprise Building Management System. The vulnerabilities were reported by Gjoko Krstic of Applied Risk. Optergy has a new version that mitigates the vulnerability. There is no indication that Krstic has been provided an opportunity to verity the efficacy of the fix.

The eight reported vulnerabilities are:

• Information exposure (2) - CVE-2019-7272 and CVE-2019-7277;
• Cross-site request forgery - CVE-2019-7273;
• Unrestricted upload of file with dangerous type - CVE-2019-7274;
• Open redirect - CVE-2019-7275;
• Hidden functionality - CVE-2019-7276
• Exposed dangerous method or function - CVE-2019-7278; and
• Use of hard-coded credentials - CVE-2019-7279

NOTE: I briefly reported on these vulnerabilities last month. Interestingly, the Applied Risk advisory describes six vulnerabilities but provided all eight of the above CVE’s.

Saturday, May 18, 2019

2 Advisories Published – 05-16-19


On Thursday the DHS NCCIC-ICS published two control system security advisories for products from Fuji Electric and Schneider Electric.

Fuji Advisory


This advisory describes an out-of-bounds read vulnerability in the Fuji Alpha7 PC Loader motor controller. The vulnerability was reported by kimiya of 9SG Security Team via the Zero Day Initiative. Fuji has a new version that mitigates the vulnerability. There is no indication that kimiya has been provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reports that a relatively low-skilled attacker with uncharacterized access could exploit this vulnerability to crash the device..

Schneider Advisory


This advisory describes a use of insufficiently random values vulnerability in the Schneider Modicon M580, Modicon M340, Modicon Premium, and Modicon Quantum products. The vulnerability was reported by David Formby and Raheem Beyah of Fortiphyd Logic and Georgia Tech. Schneider has a firmware update available for one of the products and has provided generic workarounds for the others. There is no indication that the researchers have been provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit this vulnerability to to hijack TCP connections or cause information leakage.

Wednesday, October 3, 2018

Three Advisories and Three Updates Published


Yesterday the DHS NCCIC-ICS published three control system security advisories for products from Entes, GE and Delta Electronics. They also updated previously published advisories for products from Phillips, WECOM and ABB.

Entes Advisory


This advisory describes two vulnerabilities in the Entes EMG 12, an Ethernet Modbus Gateway. The vulnerability was reported by Can Demirel of Biznet Bilisim. Entes has a new firmware version that mitigates the vulnerabilities. There is no indication that Demirel has been provided an opportunity to verify the efficacy of the fix.

The two reported vulnerabilities are:

• Improper authentication - CVE-2018-14826; and
• Information exposure in query strings in get request - CVE-2018-14822

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit the vulnerability to gain unauthorized access and could allow the ability to change device configuration and settings.

GE Advisory


This advisory describes a heap based buffer overflow in the GE Communicator application. The vulnerability was reported by kimiya, working with iDefense Labs. Newer versions of the application mitigate the vulnerability. There is no indication that kimiya has been provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit the vulnerability to execute arbitrary code or create a denial-of-service condition.

Delta Advisory


This advisory describes a stack-based buffer overflow vulnerability in the Delta ISPSoft, a PLC program development tool. The vulnerability was reported by Ariele Caltabiano (kimiya) via ZDI. Newer versions of the tool mitigate the vulnerability. There is no indication that kimiya has been provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit the vulnerability to allow an attacker to execute code under the context of the application.

Phillips Update


This update provides additional information on an advisory that was originally published on March 29th, 2018. The update adds the phrase “and/or system information” to the description provided for ‘information exposure’ vulnerabilities.

WECON Update


This update provides additional information on an advisory that was originally published on July 31st, 2018. The updated information includes:

• Two new vulnerabilities added, and
• Added a third reporting security researcher.

I would have normally expected this to be a separate advisory, but since the original advisory was based upon information provided via the Zero Day Initiative, I suspect that there was an issue on that end of the process that is being corrected here.

ABB Update


This update provides additional information on an advisory that was originally published on August 28th, 2018. The update provides new mitigation information.

Wednesday, September 12, 2018

ICS-CERT Publishes 5 Advisories and 4 Updates


Yesterday the DHS ICS-CERT published five control system security advisories for products from Siemens (3) and Fuji electric (2). They also updated three previously published advisories for products from Siemens and the Meltdown/Spectre alert.

SCALANCE Advisory


This advisory describes an improper input validation vulnerability in the Siemens SCALANCE X Switches. The vulnerability is being self-reported. Siemens has updates available for two of the three affected products and has identified mitigation measures.

ICS-CERT reports that a relatively low-skilled attacker could use publicly available exploits to remotely exploit the vulnerability to cause a denial-of-service condition.

SIMATIC Advisory


This advisory describes an improper access control vulnerability in the Siemens SIMATIC WinCC OA HMI. The vulnerability is being self-reported. Siemens has an update available to mitigate the vulnerability.

ICS-CERT reports that a relatively low-skilled attacker could remotely exploit the vulnerability to escalate their privileges in the context of the program.

TD Keypad Designer Advisory


This advisory describes an unprotected search path element vulnerability in the Siemens TD Keypad Designer. The vulnerability is being self-reported. Siemens has identified generic mitigation measures for the vulnerability.

ICS-CERT reports that a relatively low-skilled attacker with local access could exploit the vulnerability  to escalate their privileges.

V-Server Lite Advisory


This advisory describes a classic buffer overflow vulnerability in the Fuji V-Server Lite. The vulnerability was reported by Ariele Caltabiano (kimiya) via the Zero Day Initiative (ZDI). Fuji has a firmware update available to mitigate the vulnerability. There is no indication that Caltabiano has been provided an opportunity to verify the efficacy of the fix.

ICS-CERT reports that a relatively low-skilled attacker could remotely exploit the vulnerability to view sensitive information and disrupt the availability of the device.

V-Server Advisory


This advisory describes seven vulnerabilities in the Fuji V-Server. The vulnerabilities were reported by Steven Seeley (mr_me) of Source Incite via ZDI. Fuji has a new software version that mitigates the vulnerabilities. There is no indication that Seeley has been provided an opportunity to verify the efficacy of the fix.

The seven reported vulnerabilities are:

• Use after free - CVE-2018-14809;
• Untrusted pointer dereference - CVE-2018-14811;
• Heap-based buffer overflow - CVE-2018-14813;
• Out-of-bounds write - CVE-2018-14815;
• Integer underflow- CVE-2018-14817;
• Out-of-bounds read - CVE-2018-14819; and
• Stack-based buffer overflow - CVE-2018-14823

ICS-CERT reports that a relatively low-skilled attacker could use publicly available exploits to remotely exploit the vulnerabilities to allow for remote code execution on the device, causing a denial of service condition or information exposure.

Industrial Products Update


This update provides new information on an advisory that originally published on May 9th, 2017 and updated on June 15, 2017,on July 25th, 2017, on August 17th, 2017, on October 10th, on November 14th, November 28th, February 27th, 2018, May 3rd, 2018 and most recently on May 15th, 2018. The new information includes revised affected versions data and mitigation measures for:

• SINAMICS DCP w. PN; and
• SINAMICS DCM w. PN

SIMATIC Update


This update provides new information on an advisory that was originally published on May 17th, 2018. The new information includes additional mitigation measures that can be used.

OpenSSL Update


This update provides new information on an advisory that was originally published on August 14th, 2018. The new information includes revised affected versions data and mitigation measures for WinCC OA.

Meltdown/Spectre Update


This update provides new information on an alert that was originally published on January 11th, 2018 and updated on January 16th, 2018, January 17th, 2018, January 30th, 2018, February 20th, 2018, February 22nd, 2018, March 1st, 2018, and most recently on July 10th, 2018. The new information includes a link to a new Meltdown/Spectre advisory from Siemens.

Note: While this newly added advisory from Siemens and another Siemens advisory on the older versions of Meltdown/Spectre address newer versions of the vulnerability, ICS-CERT has failed to provide any information (or links to information) about these new problems.

Friday, August 11, 2017

ICS-CERT Publishes 5 Advisories

Yesterday the DHS ICS-CERT published five control system security advisories for products from ABB, Fuji Electric, Solar Controls (2), and SIMPlight.

ABB Advisory


This advisory describes a relative path traversal vulnerability in the ABB SREA-01 and SREA-50 remote monitoring tools. The vulnerability was reported by Bertin Jose and Fernandez Ezequiel. HMS Industrial Networks Ab provided a patch to correct the issue, but ABB has only tested it on the SREA-01. These are unsupported legacy products. There is no indication that the researchers have been provided an opportunity to verify the efficacy of the fix.

ICS-CERT reports that a relatively low skilled attacker could use publicly available exploits to remotely exploit the vulnerability to access files on the affected products’ file systems, view data, change configuration, retrieve password hash codes, and potentially insert and send commands to connected devices without authorization.

NOTE: ABB reports that exploit code was published on github by the researchers.

Fuji Advisory


This advisory describes multiple vulnerabilities in the Fuji Monitouch V-SFT screen configuration software. The vulnerabilities were reported by Fritz Sands and kimiya via the Zero Day Initiative. Fuji has released a new version to mitigate the vulnerabilities. There is no indication that the researchers have been provided an opportunity to verify the efficacy of the fix.

The three reported vulnerabilities are:

• Stack-based buffer overflow - CVE-2017-9659;
• Heap-based buffer overflow - CVE-2017-9660; and
• Improper privilege management - CVE-2017-9662

ICS-CERT reports that a relatively low skilled attacker could remotely exploit the vulnerabilities to allow remote code execution or cause the software that the attacker is accessing to crash. The improper privilege management vulnerability could allow an attacker with local access to escalate privileges.

WATTConfig Advisory


This advisory describes an uncontrolled search path element vulnerability in the Solar Controls WATTConfig M Software. The vulnerability was reported by Karn Ganeshen. ICS-CERT reports that Solar Controls has not responded to requests to coordinate with NCCIC/ICS-CERT.

ICS-CERT reports that a relatively low skilled attacker with uncharacterized access could exploit the vulnerability to allow arbitrary code execution.

HCDownloader Advisory


This advisory describes an uncontrolled search path element vulnerability in the Solar Controls Heating Control Downloader (HCDownloader). The vulnerability was reported by Karn Ganeshen. ICS-CERT reports that Solar Controls has not responded to requests to coordinate with NCCIC/ICS-CERT.

ICS-CERT reports that a relatively low skilled attacker with uncharacterized access could exploit the vulnerability to allow arbitrary code execution.

SIMPlight Advisory


This advisory describes an uncontrolled search path element vulnerability in the the SIMPlight SCADA Software. ). The vulnerability was reported by Karn Ganeshen. ICS-CERT reports that Solar Controls has not responded to requests to coordinate with NCCIC/ICS-CERT.


ICS-CERT reports that a relatively low skilled attacker with uncharacterized access could exploit the vulnerability to allow arbitrary code execution.

Thursday, July 13, 2017

ICS-CERT Publishes 3 Advisories

Today the DHS ICS-CERT published three control system security advisories for products from Siemens (2) and GE. They also published the latest version of the ICS-CERT Monitor and a new FY 2016 Assessment Report.

SIMATIC Advisory


This advisory describes two vulnerabilities in the Siemens SIMATIC Sm@rtClient Android App. The vulnerabilities were reported by Karsten Sohr and Timo Glander from the TZI at the University of Bremen. Siemens has released a new version to mitigate the vulnerabilities. There is no indication that the researchers have been provided an opportunity to verify the efficacy of the fix.

The two vulnerabilities are:

• Channel accessible by non-endpoint - CVE-2017-6870; and
• Authentication bypass using alternative bypass or channel - CVE-2017-6871

ICS-CERT reports that a relatively low skilled attacker could remotely exploit the vulnerability to read and modify data within a Transport Layer Security TLS session. The Siemens security bulletin reports that the second vulnerability requires “physical access to an unlocked mobile device”.

GE Advisory


This advisory describes a heap-based buffer overflow vulnerability in the GE Communicator application. The vulnerability was reported by Kimiya, working with iDefense Labs. GE recommends upgrading to the newst version that mitigates the vulnerability. There is no indication that Kimiya was provided an opportunity to verify the efficacy of the fix.

ICS-CERT reports that a relatively low skilled attacker could remotely exploit the vulnerability to execute arbitrary code or create a denial-of-service condition.

Comment: Once again a previously released version (revision date 02-18-17) fixes a security issue that was not identified in the Release notes. Remarkably lucky programmers that could fix an unidentified problem. Those release notes did identify another vulnerability in earlier versions that was corrected but has not apparently been reported to ICS-CERT; an unused software graphic library which was identified as a potential Microsoft® ActiveX security vulnerability.

SiPass Advisory


This advisory describes multiple vulnerabilities in the Siemens SiPass integrated access control system. Siemens is self-reporting the vulnerabilities. Siemens has produced a new version that mitigates the vulnerabilities.

The reported vulnerabilities are:

• Improper authentication - CVE-2017-9939;
• Improper privilege management - CVE-2017-9940;
• Channel accessible by non-endpoint - CVE-2017-9941; and
• Storing passwords in a recoverable format - CVE-2017-9942

ICS-CERT reports that a relatively low skilled attacker with unauthenticated network access could remotely exploit these vulnerabilities to perform administrative operations.

ICS-CERT Monitor


The ICS-CERT Monitor for May-June 2017 provides a little more useful information than we have been seeing in this publication of late. There are two brief but informative articles that should be read by all facility security managers:

• Data Classification for Recovery Planning (pg 2); and
• Cybersecurity Defense (pg 2)

The first outlines the risk assessment process used to determine backup rates for data. The second briefly discusses the importance of wet-ware (personnel) training to aid the security process. Both could have been fleshed out quite a bit, but given the glossy corporate report format that really is not practical. It would be helpful if ICS-CERT (or someone) did a fact sheet or white paper on both of these important topics. If someone knows of one, please point me at it.

FY 2016 Assessment Report


Well, the FY 2016 Assessment Report is not be published quite as late in the year as the 2015 report was, but you have to wonder why it took so long to publish such an uninformative 20 page report. If you read my review of the 2015 report, you already know most of the problems with this version.

One disheartening fact did jump off the page a scream at me, ‘Physical Access Control’ jumped back onto the ‘Top Six Weakness’ categories reported in the 130 assessments conducted last year. Again, you have to be careful of the numbers here because it is quite possible that some of the facilities had more than one assessment (three different assessment types) conducted.


Oh well, read it. Be careful of how much respect you give for the individual numbers (and those will be much hyped in the main stream and cybersecurity press), but look for the small pieces of valuable information (for example on page 11 “Keys allowing physical access may be out of the facilities’ control, possibly allowing unauthorized personnel to access critical or sensitive areas.”).

Tuesday, January 27, 2015

ICS-CERT Publishes Two Advisories and an Update

Today the DHS ICS-CERT published two new advisories and updated a two week old advisory. The new advisories addressed vulnerabilities in control system applications from Schnedier and Magnetrol. The update was for the CodeWrights advisory.

CodeWrights Update

This update provides a slight expansion of the scope of the vulnerability. It explains that “the exploit is possible from any adjacent network between the FDT/DTM frame application and the HART transmitter on the 4 mA to 20 mA current loop”. The previous version noted only that access “to the 4 mA to 20 mA HART current loop is required to exploit this vulnerability”.

This slightly weakens the claim that crafting “a working exploit for this vulnerability would be difficult”.

Schneider Advisory

This advisory describes a stack-based buffer overflow vulnerability in a number of Schneider products. The original discover by Ariele Caltabiano (kimiya) with HP’s Zero Day Initiative (ZDI) dealt with the vulnerability in the SoMove Lite software package. Schneider subsequently discovered the same vulnerability in a number of device type managers (DTM) containing the same DLL. Schneider has produced a patch that mitigates the vulnerability, but there is no mention if kimiya has been given the opportunity to validate the effectiveness of the patch.

ICS-CERT reports that a relatively low skilled attacker could remotely exploit this vulnerability to execute arbitrary code on the affected systems. Schneider reports that the patch will replace the vulnerable FTD1 DLL.

Magnetrol Advisory

This advisory is kind of a waste of time. It describes the same CodeWrights vulnerability described in the advisory that was updated today. In fact, Magnetrol is one of the companies listed in the CodeWrights advisory as potentially having vulnerable HART DTM library is some of their products. The whole point of the CodeWrights advisory was that ICS-CERT could update that advisory when some vendor announced their implementation of a fix for the vulnerability in their equipment.

Oh well, Magnetrol has integrated the CodeWrights update and issued revised HART DTM library extensions.


BTW: ICS-CERT still has not mentioned the Siemens report of this vulnerability in some of their systems. I had expected them in the next (read this one) CodeWrights update to add Siemens to the list of affected vendors. I guess that I am just expecting too much from ICS-CERT.

I owe ICS-CERT a major public apology. The ‘missing’ Siemens vulnerability report deals with the NTP issue not the CodeWrights Vulnerability.
 