Tuesday, January 5, 2021

6 Advisories Published – 1-5-21

Today the CISA NCCIC-ICS published six control system security advisories for products from Delta Electronics (2), Red Lion, GE, Panasonic and Schneider.

CNCSoft Advisory

This advisory describes a stack-based buffer overflow vulnerability in the Delta CNCSoft ScreenEditor. The vulnerability was reported by Kimiya via the Zero Day Initiative. Delta has an update that mitigates the vulnerability. There is no indication that Kimiya has been provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reports that a relatively low-skilled attacker with uncharacterized access could exploit the vulnerability to allow arbitrary code execution.

DOPSoft Advisory

This advisory describes two vulnerabilities in the Delta DOPSoft software. The vulnerability was reported by Kimiya via the Zero Day Initiative. Delta has an update that mitigates the vulnerability. There is no indication that Kimiya has been provided an opportunity to verify the efficacy of the fix.

The two reported vulnerabilities are:

• Out-of-bounds write - CVE-2020-27275, and

• Untrusted pointer dereference - CVE-2020-27277

NCCIC-ICS reports that a relatively low-skilled attacker with uncharacterized access could exploit the vulnerability to allow arbitrary code execution.

Red Lion Advisory

This advisory describes three vulnerabilities in the Red Lion Crimson 3.1 programming software. The vulnerabilities were reported by Marco Balduzzi, Ryan Flores, Philippe Lin, Charles Perine, Ryan Flores, Rainer Vosseler via ZDI. Red Lion has a new version that mitigates the vulnerabilities. There is no indication that the researchers were provided an opportunity to verify the efficacy of the fix.

The three reported vulnerabilities are:

• Null pointer dereference - CVE-2020-27279,

• Missing authentication for critical function - CVE-2020-27285, and

• Improper resource shutdown - CVE-2020-27283

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit the vulnerability to allow an attacker to create a denial-of-service condition, read and modify the database, and leak memory data.

GE Advisory

This advisory describes two vulnerabilities in the GE Reason RT43X Clocks. The vulnerabilities were reported by Tom Westenberg of Thales UK. GE has a new firmware version that mitigates the vulnerabilities. There is no indication that Westenberg has been provided an opportunity to verify the efficacy of the fix.

The two reported vulnerabilities are:

• Code injection - CVE-2020-25197, and

• Use of hard-coded cryptographic key - CVE-2020-25193

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit the vulnerabilities to allow an authenticated remote attacker to execute arbitrary code on the system or intercept and decrypt encrypted traffic.

NOTE: I (very) briefly mentioned the GE advisory for these vulnerabilities back in November.

Panasonic Advisory

This advisory describes an out-of-bounds read vulnerability in the Panasonic FPWIN Pro programming software. The vulnerability was reported by Francis Provencher via ZDI. Panasonic has a new version that mitigates the vulnerability. The is no indication that Provencher has been provided an opportunity to verify the efficacy of the fix.

NCCIC-ICS reports that a relatively low-skilled attacker with uncharacterized access could exploit this vulnerability to  allow remote code execution.

Schneider Advisory

This advisory describes three vulnerabilities in the Schneider Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy products. The vulnerabilities were reported (here and here) by Kai Wang of Fortinet's FortiGuard Labs. Schneider continues to work on mitigation measures for supported versions of the affected products.

The three reported vulnerabilities were:

• Out-of-bounds read - CVE-2020-7562,

• Out-of-bounds write - CVE-2020-7563, and

• Classic buffer overflow - CVE-2020-7564

NCCIC-ICS reports that a relatively low-skilled attacker could remotely exploit the vulnerabilities to allow write access and the execution of commands, which could result in data corruption or a web server crash.

NOTE: I briefly described these vulnerabilities back in November.

NCCIC-ICS Updates

NCCIC-ICS also published five updates today. I will cover them in a separate blog post.

Saturday, November 14, 2020

Public ICS Disclosures – Week of 11-07-20

This week we have eight vendor disclosures for products from Schneider (7) and Thales Group. We also have nine updates for advisories for products from Schneider (5), Siemens (2), Carestream and Rockwell.

Schneider Advisories

Schneider published an advisory describing three vulnerabilities in the web servers of their Modicon M340, Modicon Quantum and Modicon Premium Legacy products. The vulnerabilities were reported (here and here) by Kai Wang of Fortinet's FortiGuard Labs. Schneider is working on mitigation measures for those affected products that are not end-of-life.

The three reported vulnerabilities are:

• Out-of-bounds read - CVE-2020-7562,

• Out-of-bounds write - CVE-2020-7563, and

• Classic buffer overflow - CVE-2020-7564

 

Schneider published an advisory describing an improper privilege management vulnerability in their EcoStruxure™ Operator Terminal Expert runtime (Vijeo XD). The vulnerability was reported by Lasse Trolle Borup of Danish Cyber Defence. Schneider has a service pack that mitigates the vulnerability. There is no indication that the researchers have been provided an opportunity to verify the efficacy of the fix.

 

Schneider published an advisory describing nine vulnerabilities in their Interactive Graphical SCADA System (IGSS) product. The vulnerabilities were reported by kimiya via the Zero Day Initiative. Schneider has a new version that mitigates the vulnerabilities. There is no indication that kimiya has been provided an opportunity to verify the efficacy of the fix.

The nine reported vulnerabilities are:

• Improper restriction of operations within the bounds of a memory buffer (4) – CVE-2020-7550, CVE-2020-7551, CVE-2020-7552, and CVE-2020-7554,

• Out-of-bounds write (4) - CVE-2020-7553, CVE-2020-7555, CVE-2020-7556, and CVE-2020-7558, and

• Out-of-bounds read - CVE-2020-7557

 

Schneider published an advisory describing seven vulnerabilities in their EcoStruxure Building Operation (EBO) product offerings. The vulnerabilities were reported by Luis Vázquez, Francisco Palma, and Diego León of Zerolynx, and Alessandro Bosco, Luca Di Giuseppe, Alessandro Sabetta, Massimiliano Brolli of TIM Security Red Team Research. Schneider has a version that mitigates the vulenrabilities. There is no indication that the researchers have been provided an opportunity to verify the efficacy of the fix.

The seven reported vulnerabilities are:

• Unrestricted upload of file with dangerous type - CVE-2020-7569,

• Cross-site scripting stored - CVE-2020-7570,

• Cross-site scripting reflected - CVE-2020-7571,

• Improper restriction of XML external entity reference - CVE-2020-7572,

• Improper access control - CVE-2020-7573,

• Windows unquoted search path - CVE-2020-28209, and

• Cross-site scripting - CVE-2020-28210

 

Schneider published an advisory describing four vulnerabilities in their Modicon M221 product. The vulnerabilities were reported by Yehuda Anikster and Rei Henigman of Claroty, and Seok Min Lim and Bryon Kaan of Trustwave (here). Schneider provides generic work arounds to mitigate the vulnerabilities.

The four reported vulnerabilities are:

• Inadequate encryption strength - CVE-2020-7565,

• Small space of random values - CVE-2020-7566,

• Missing encryption of sensitive data - CVE-2020-7567, and

• Exposure of sensitive data to an unauthorized actor - CVE-2020-7568

NOTE: The Trustwave report contains proof-of-concept code.

 

Schneider published an advisory describing an improper access control vulnerability in their Easergy T300 remote terminal unit. The vulnerability was reported by Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar. Schneider has a new version that mitigates the vulnerability. There is no indication that the researchers have been provided an opportunity to verify the efficacy of the fix.


Schneider published an advisory discussing the Drovorub malware and its impact on their Q Data Radio and J Data Radio devices. Schneider is providing generic workarounds pending further work on mitigating the vulnerabilities.

Thales Advisory

Thales Group published an advisory for their Sentinel RMS License Manager. The advisory is only available to registered customers. We should expect to see various vendors incorporating the fix for this in their affected products.

Schneider Updates

Schneider published an update for their Ripple20 advisory. The new information includes adding mitigation measures for:

• eIFE Ethernet Interface for MasterPact MTZ drawout circuit breakers,

• IFE Ethernet Interface for ComPact, PowerPact, and MasterPact circuit breakers, and

• IFE Gateway

 

Schneider published an update for their EcoStruxure advisory that was originally published on May 12th, 2020 and most recently updated on June 9th, 2020. The new information includes adding mitigation measures for CVE-2020-7495 & CVE-2020-7497.

 

Schneider published an update for their Modicon M218/M241/M251/M258 Logic Controllers advisory that was originally published on April 14th, 2020. The new information includes adding mitigation measures for M258.

 

Schneider published an update for their Modicon Controllers advisory that was originally published on March 20th, 2020. The new information includes adding mitigation information for CVE-2020-7475.

 

Schneider published an update for their Modicon M580 controller advisory that was originally published on October 8th, 2019. The new information includes adding mitigation information for CVE-2019-6848 and CVE-2019-6849.

Siemens Updates

Siemens published an update for their CodeMeter advisory. The new information includes adding SICAM 230 to the list of affected versions including mitigation measures.


Siemens published an update for their GNU/Linux advisory that was originally published in 2018 and most recently updated on October 13th, 2020. The new information includes adding:

• CVE-2020-10769,

• CVE-2020-14314,

• CVE-2020-25211, and

• CVE-2020-25641

Carestream Update

Carestream published an update [.PDF download link] for their Bad Neighbor advisory. The new information includes lists of affected and unaffected products.

Rockwell Update

Rockwell published an update for their Urgent/11 advisory. The new information includes mitigation measures for ControlLogix 5580 and CompactLogix products.


 