Showing posts with label TCCA. Show all posts
Showing posts with label TCCA. Show all posts

Tuesday, October 1, 2024

TCCA Chemical Hazards

The ongoing chemical incident at the Bio-Lab facility in Conyers, GA has caused significant damage to the Bio-Lab facility (not yet fully documented in the press), the evacuation of thousands of people in the area surrounding the facility, and the on-again-off-again shelter in place for even more thousands of residents outside of the evacuation zone. The source of these problems is the chemical trichloroisocyanuric Acid (TCCA), a bleaching agent commonly used for the disinfection of swimming pools and spas. Typically sold in small quantities most people do not consider this to be a dangerous chemical.

As I noted in this morning's post, Bio-Lab has had problems in the past with safety incidents related to TCCA. The CSB’s report (pg 13) on the May 2020 incidents describes the hazards associated with TCCA:

“Trichloroisocyanuric Acid (TCCA), a chlorinating agent, is often used as a sanitizer for swimming pools and hot tubs. It is a white solid substance manufactured at the Bio-Lab facility and available as a powder, compacted tablets, and granules (Figure 2). In large bodies of water, such as pools, TCCA breaks down slowly to release hypochlorous acid (HClO), as shown in Figure 3, which kills bacteria, algae, and other microorganisms as intended. When TCCA instead comes in contact with a small amount of water, it can experience a chemical reaction causing heat generation [1, pp. 2-3] and the decomposition of the TCCA. When TCCA reacts and decomposes, it produces toxic chlorine gas [2, p. 2622] and can produce explosive nitrogen trichloride [3, p. 1]. According to the U.S. Environmental Protection Agency (EPA), “Even a small amount of water splashed on the [pool] chemical may in some cases trigger a strong reaction” [1]. Water-reactive materials may violently react, produce toxic or other hazardous gases, or evolve enough heat to cause self-ignition or ignition of nearby combustibles upon water exposure [4, pp. 400-17]. TCCA is a Class 1 oxidizer, and TCCA “[r]eacts with combustible materials, ammonia salts, or foreign substances, resulting in fire [5, pp. 49-148]. Bio-Lab’s TCCA safety data sheet (SDS) states that a fire involving TCCA should be flooded with water.”

What this means when a storage facility for a TCCA manufacturer becomes involved in an incident, is that past a certain size, the situation becomes unmanageable. If the building collapses from the affects of the fire (as has appeared to have happened this weekend) an indeterminate number of individual containers are going to become compromised. Non-flooding amounts of water are going inevitably come in contact with the exposed TCCA, starting the decomposition process all over again. Heat from the reaction in the newly damaged container will provide sufficient heat to compromise additional plastic containers that had not already been damaged. Either additional water will reach these containers, or the exotherm from nearby containers will increase the temperature to begin the decomposition process in a new site. Shifting wreckage will damage further containers. And so on and so on until all of the containers are reduced to melted plastic slag. Hopefully, that will happen before anyone starts to tear down the remains of the damaged building.

CSB Sends Team to Conyers, GA Fire and Chlorine Release Incident

Yesterday, the Chemical Safety Board (CSB) announced that they had sent a team to investigate the major chemical fire that occurred on September 29 at the Bio-Lab facility in Conyers, GA. According to early news reports (here, here, and here) the incident started out as a minor fire on the roof of the chemical manufacturing facility, but greatly expanded when fire fighting water came into contact with a common pool chemical {trichloroisocyanuric acid (TCCA)}, initiating a chemical decomposition reaction that released chlorine gas (and oxygen, hence the reason that PHMSA classifies the chemical as an oxidizer not an inhalation hazard) into the atmosphere. The incident resulted in the evacuation of 17,000 people, the isolation of an additional 90,000 people under a shelter-in-place warning, and the closure of I 20.

The announcement reports that:

“The CSB has investigated the Bio-Lab facility [link added] in Conyers before.  In September 2020, the CSB investigated a chemical reaction and decomposition at the facility which released a plume of hazardous chemicals, including chlorine, that exposed Bio-Lab personnel and nine firefighters to dangerous fumes.  Surrounding businesses in the area were evacuated, and a portion of Interstate 20 near the facility was closed for six hours.”

The fact that the CSB has sent a team to the Conyers, GA site does not necessarily mean that the agency will conduct an official investigation that will result in formal report. Since the CSB is not a regulatory agency, there is no requirement for an investigation in every significant incident. I suspect, however, that in this case, with the wide-spread, on-going news coverage, and the significant off-site impact, that the agency will conduct a formal investigation. And, of course, it would allow them to once again hit at the EPA and OSHA for their continued failure to regulate reactive chemical hazards.

While it is late in the swimming pool season, the extensive damage caused by this incident (the news reports indicated that at least one building on site has collapsed), will be expected to have a major impact on the availability of pool/spa disinfectant chemicals into (and probably through) next year.

 